Menu
Case History

Online heat exchangers gain improved performance and recover $60,000 in lost production per day for a US refinery through utilizing FQE® Solvent-H+

Results Achieved

R
Increased crude input by
15,000 bbls/day
R
Recover $60,000 in lost production per day
R
Zero downtime in application

Chemicals Utilized

Award-winning asphaltene dispersant and anti-foulant

During a fall outage, a large refinery in the western United States sought out a solution to remove asphaltene fouling and improve the performance of eight online heat exchangers in their crude unit pre-heat train.
Exchanger U-Coefficients

The graph (provided by the client) shows the effectiveness of FQE® Solvent-H+ at increasing the efficiency of the online crude unit heat exchangers.

To dissolve and disperse the heavy hydrocarbons and asphaltenes responsible for efficiency reductions, an online treatment program utilizing FQE Solvent-H+ was applied.

Optimizing the surface interactions of the chemical required adequate surface contact time to ensure an effective treatment. The online high-intensity chemical injection program was completed over 48 hours, with operating temperatures ranging from 400ºF (204ºC) to a maximum of 700ºF (371ºC).

Following the online high-intensity treatment injection in late September, the u-coefficients of each exchanger witnessed increases of up to 120% over the following 30 days. These values leveled off over the next 30 days. Though, post-injection u-coefficients typically remained at least 50% higher than the pre-injection values.

Following the online high-intensity application process, the client was able to confirm several key benefits:

1

Increased System Flow

The client was able to increase crude input by 15,000 bbls/day

2

Millions of Dollars in Recovered Revenue

Due to the increased efficiency and flow and conservatively estimating a $40/bbl market price, the client was able to recover $60,000 in lost production per day. Which equates to over $1.8 million in an average month.

3

Ease of Application and Reliability

FQE Solvent-H+ created no solid by-products as the organic solids remain liquefied, unable to precipitate from the mixture as latent solids. Any potential scaling or blockage issues tied to solids were avoided. As a result, the client was able to improve the reliable operation of the refinery, without shutting down, while effectively addressing their fouling concerns.

As a result of the successful online high-intensity treatment to remove the built-up asphaltene deposits in our client’s facility, we have increased equipment efficiency and production volumes, lowered operating costs and increased reliability through the ease of application.

Ready to learn more?

Get in touch with a technical sales representative.