Menu
Case History

Within 36 hours a crude oil storage tank containing heavy sour crude was decontaminated of benzene, H2S, and LEL’s safely with no pyrophoric combustion

Results Achieved

R
Within 36 hours all benzene, H2S and LEL levels were zero
R
No iron sulphide combustion
R
Waste water treatment compatible

Chemicals Utilized

Award-winning asphaltene dispersant and anti-foulant

FQE LEL-Vapor

Rapid absorption and encapsulation of vapor-state hydrocarbons

H2S scavenger for the rapid and permanent elimination of H2S

Non-hazardous product for effective control of pyrophoric iron deposits

A world scale petroleum refinery scheduled an outage to clean and decontaminate a crude oil storage tank containing heavy sour crude.

The site concerns included LEL and benzene levels, high hydrogen sulfide presence and pyrophoric iron scales. We previously performed benzene encapsulation and hydrogen sulfide management in other areas of the facility, the client requested we perform this application. The client’s needs were to bring the LEL level below 2%, benzene concentration under 0.5 ppm, no pyrophoric iron combustion and to not impact waste water operations.

Tank 602 is a 200’ diameter vessel with a floating roof with an estimated 15’ of heavy sludge. Samples taken of the vessel contents indicated a high asphaltene content and the presence of iron sulfide scale. Air samples of the vessel prior to beginning the work revealed 100% LEL, 40 ppm hydrogen sulfide and 33 ppm benzene.

Prior to our arrival, the client drained the free hydrocarbons from the vessel. Circulation equipment was stationed and a tank bottom circulation was initiated from four manway locations using LCO cutter stock and a 5% concentration of FQE® Solvent-H to solvate wax and asphaltenes present in the crude sludge.

Following circulation of the tank bottoms, the fluidized organic solids were pumped out of TK T-602 to adjacent crude storage following analysis and approval by plant supervision.

Following evacuation of the tank oil liquid, an aqueous solution of FQE LEL-Vapor and FQE H2S Scavenger were introduced into the tank via 3D nozzle from the tank roof to eliminate the resident benzene, H2S and bring down the LEL to specifications.

Within 36 hours of chemical addition all benzene / H2S and LEL levels were zero. A 2% solution of FQE Pyrophoric was introduced into the cleaning liquid at the completion of vapor space scrubbing to control iron sulfide concerns. Maintenance activities were able to be started immediately following draining of the final water rinse. Benzene / LEL levels did not rise and there was no iron deposit combustion. The cleaning solution was sent directly to waste water treatment without incident. 

Ready to learn more?