Natural Gas Plant Degassing and Descaling

Results Achieved

Within 24 hours all benzene, H2S and LEL levels were zero

Equipment decontaminated of tars, gases, and oil

Inspection found nominal scale deposits in dead areas of equipment

U-values on heat exchangers improved, decreased fouling factor average of 0.054 to 0.04.

Chemical profiles

fqe-lel-v-30

Rapid absorption of vapor-state hydrocarbons in an innovative encapsulant for effective decontamination and degassing of hydrocarbon processing equipment. Significantly reduces equipment outage times.

Visit Degassing Page

fqe-degreaser-acho-30

Alkaline degreaser for heavy oils/greases, compatible with stainless steel, rapid oil separation, caustic.

fqe-scale-solv-30

FQE™ Scale-Solv contains wetting agents, corrosion inhibitors, sequestering agents and accelerators for effective cleaning of difficult scales such as barium sulfate. Will effectively dissolve silicates.

fqe-h2s-30

Designed for instantaneous and permanent elimination of Hydrogen Sulfide present in refining and other process equipment. Safe and effective permanent removal of the toxicity of Hydrogen Sulfide.

Visit Hydrogen Sulfide Page

A natural gas processing plant scheduled an outage to decontaminate operating equipment prior to conducting maintenance work.

 

The plant’s production capacity was negatively impacted by debris accumulation and chemical cleaning was scheduled to increase production and improve heating efficiency.

 

The client’s needs were to bring the LEL level below 1%, benzene concentration under 1.0 ppm and to accomplish the degassing/decontamination within 48 hours. Following the organic decontamination, the plant wanted equipment typically fouled with water-born scales to be chemically cleaned to improve product through-put and heat efficiency. The plant feed is wet natural gas with hydrogen sulfide at over 100 ppm.

 

The process areas to be cleaned and decontaminated were the glycol contactor, the de-propanizer, de-ethanizer towers, the caustic wash system and all associated cross heat exchangers and piping. The equipment is typically fouled with organic tars entrained in the incoming gas stream and water-born inorganic scale.

 

The chemical products were FQE™ LEL-V, FQE™ Degreaser-ACMO, FQE™ Scale-Solv and FQE™ H2S. Different concentrations were used in each system. The decontamination process was initiated with a combination of FQE Degreaser-ACMO and FQE H2S to de-oil/remove organic debris and hydrogen sulfide gas. Following the system de-oiling, FQE LEL-V was used to degas the equipment of light-end hydrocarbon gases. After the equipment was properly degassed and de-oiled the equipment was circulated with FQE ScaleSolv to remove any inorganic scales that were present inside of the equipment. Piping, heat exchangers and where possible, operating towers were included in a single loop chemical cleaning to optimize the efficiency of decontamination.

 

The equipment was decontaminated of tars, oil, benzene / LEL and hydrogen sulfide levels were zero within 24 hours. De-scaling the equipment required an additional 10 hours to complete. Maintenance activities were able to be started upon draining the equipment and a water rinse. The equipment was free of oils, gases and inspection found nominal scale deposits in dead areas of the equipment.

 

Inspections on heat exchangers were acceptable with subsequent improved U-values, increased duty and a decreased fouling factor average of 0.054 to 0.04.

Download a PDF copy of this case history