Chemical Decontamination of SRU Sump

Results Achieved

Complete elimination of hydrogen sulfide levels

Zero LEL’s

5 hours total time

Chemical profiles

fqe-h2s-30

Designed for instantaneous and permanent elimination of hydrogen sulfide present in refining and other process equipment. The most efficient abatement product on the market capable of removing 3 moles of sulfide to 1 mole of active chemical.

Visit Hydrogen Sulfide Page

A large petroleum refinery plant in the Southern United States used our FQE H2S product to eliminate high hydrogen sulfide levels in the SRU plant sump.

 

The sump contained contaminated water at dangerously high levels of hydrogen sulfide over 8,000 ppm. The typical cleaning process resulted in work stoppage and extended purging of air through the system to carbon canisters to void the equipment of hazardous levels of hydrogen sulfide.

 

A solution of FQE H2S was injected into the sump contents and the liquid was circulated for 1 hour to eliminate the dissolved hydrogen sulfide. After 1 hour of circulation the air space above the sump fluids were treated by spray to remove the vapor-phase hydrogen sulfide. The sump air space was checked and found to be void of H2S with sump liquid having non-detectable hydrogen sulfide.

 

The total time for decontamination was 5 hours. The waste water was sent directly to waste water treatment without delay. Previous decontamination work done required much more time and the high expense of activated carbon canisters.